Nixpkgs security tracker

Login with GitHub

Suggestions search

With package: proteus

Found 7 matching suggestions

View:
Compact
Detailed
Untriaged
Permalink CVE-2026-42958
8.4 HIGH
  • CVSS version (CVSS): 4.0
  • Attack Vector (AV): Local (L)
  • Attack Complexity (AC): Low (L)
  • Attack Requirement (AT): None (N)
  • Privileges Required (PR): None (N)
  • User Interaction (UI): Active (A)
  • Vulnerable System Impact Confidentiality (VC): High (H)
  • Vulnerable System Impact Integrity (VI): High (H)
  • Vulnerable System Impact Availability (VA): High (H)
  • Subsequent System Impact Confidentiality (SC): None (N)
  • Subsequent System Impact Integrity (SI): None (N)
  • Subsequent System Impact Availability (SA): None (N)
  • Modified Attack Vector (MAV): Local (L)
  • Modified Attack Complexity (MAC): Low (L)
  • Modified Attack Requirement (MAT): None (N)
  • Modified Privileges Required (MPR): None (N)
  • Modified User Interaction (MUI): Active (A)
  • Modified Vulnerable System Impact Confidentiality (MVC): High (H)
  • Modified Vulnerable System Impact Integrity (MVI): High (H)
  • Modified Vulnerable System Impact Availability (MVA): High (H)
  • Modified Subsequent System Impact Confidentiality (MSC): Negligible (N)
  • Modified Subsequent System Impact Integrity (MSI): Negligible (N)
  • Modified Subsequent System Impact Availability (MSA): Negligible (N)
  • Safety (S): Not Defined (X)
  • Automatable (AU): Not Defined (X)
  • Recovery (R): Not Defined (X)
  • Value Density (V): Not Defined (X)
  • Vulnerability Response Effort (RE): Not Defined (X)
  • Provider Urgency (U): Not Defined (X)
  • Confidentiality Req. (CR): Not Defined (X)
  • Integrity Req. (IR): Not Defined (X)
  • Availability Req. (AR): Not Defined (X)
  • Exploit Maturity (E): Not Defined (X)
created 2 weeks, 3 days ago Activity log
  • Created suggestion
Use After Free in Labcenter Proteus

The application contains a use-after-free vulnerability that can be exploited to cause memory corruption while parsing specially crafted files. This could allow an attacker to execute arbitrary code in the context of the current process.

Affected products

Proteus
  • ==9.1_SP4_Build-42914

Matching in nixpkgs

pkgs.proteus

Guitar amp and pedal capture plugin using neural networks

  • nixos-unstable 1.2
    • nixpkgs-unstable 1.2
    • nixos-unstable-small 1.2
  • nixos-26.05 1.2
    • nixos-26.05-small 1.2
    • nixpkgs-26.05-darwin 1.2
Untriaged
Permalink CVE-2026-49033
8.4 HIGH
  • CVSS version (CVSS): 4.0
  • Attack Vector (AV): Local (L)
  • Attack Complexity (AC): Low (L)
  • Attack Requirement (AT): None (N)
  • Privileges Required (PR): None (N)
  • User Interaction (UI): Active (A)
  • Vulnerable System Impact Confidentiality (VC): High (H)
  • Vulnerable System Impact Integrity (VI): High (H)
  • Vulnerable System Impact Availability (VA): High (H)
  • Subsequent System Impact Confidentiality (SC): None (N)
  • Subsequent System Impact Integrity (SI): None (N)
  • Subsequent System Impact Availability (SA): None (N)
  • Modified Attack Vector (MAV): Local (L)
  • Modified Attack Complexity (MAC): Low (L)
  • Modified Attack Requirement (MAT): None (N)
  • Modified Privileges Required (MPR): None (N)
  • Modified User Interaction (MUI): Active (A)
  • Modified Vulnerable System Impact Confidentiality (MVC): High (H)
  • Modified Vulnerable System Impact Integrity (MVI): High (H)
  • Modified Vulnerable System Impact Availability (MVA): High (H)
  • Modified Subsequent System Impact Confidentiality (MSC): Negligible (N)
  • Modified Subsequent System Impact Integrity (MSI): Negligible (N)
  • Modified Subsequent System Impact Availability (MSA): Negligible (N)
  • Safety (S): Not Defined (X)
  • Automatable (AU): Not Defined (X)
  • Recovery (R): Not Defined (X)
  • Value Density (V): Not Defined (X)
  • Vulnerability Response Effort (RE): Not Defined (X)
  • Provider Urgency (U): Not Defined (X)
  • Confidentiality Req. (CR): Not Defined (X)
  • Integrity Req. (IR): Not Defined (X)
  • Availability Req. (AR): Not Defined (X)
  • Exploit Maturity (E): Not Defined (X)
created 2 weeks, 3 days ago Activity log
  • Created suggestion
Stack-Based Buffer Overflow in Labcenter Proteus

The application contains a stack-based buffer overflow vulnerability that can be exploited by an attacker to execute arbitrary code.

Affected products

Proteus
  • ==9.1_SP4_Build-42914

Matching in nixpkgs

pkgs.proteus

Guitar amp and pedal capture plugin using neural networks

  • nixos-unstable 1.2
    • nixpkgs-unstable 1.2
    • nixos-unstable-small 1.2
  • nixos-26.05 1.2
    • nixos-26.05-small 1.2
    • nixpkgs-26.05-darwin 1.2
Untriaged
Permalink CVE-2026-42953
8.4 HIGH
  • CVSS version (CVSS): 4.0
  • Attack Vector (AV): Local (L)
  • Attack Complexity (AC): Low (L)
  • Attack Requirement (AT): None (N)
  • Privileges Required (PR): None (N)
  • User Interaction (UI): Active (A)
  • Vulnerable System Impact Confidentiality (VC): High (H)
  • Vulnerable System Impact Integrity (VI): High (H)
  • Vulnerable System Impact Availability (VA): High (H)
  • Subsequent System Impact Confidentiality (SC): None (N)
  • Subsequent System Impact Integrity (SI): None (N)
  • Subsequent System Impact Availability (SA): None (N)
  • Modified Attack Vector (MAV): Local (L)
  • Modified Attack Complexity (MAC): Low (L)
  • Modified Attack Requirement (MAT): None (N)
  • Modified Privileges Required (MPR): None (N)
  • Modified User Interaction (MUI): Active (A)
  • Modified Vulnerable System Impact Confidentiality (MVC): High (H)
  • Modified Vulnerable System Impact Integrity (MVI): High (H)
  • Modified Vulnerable System Impact Availability (MVA): High (H)
  • Modified Subsequent System Impact Confidentiality (MSC): Negligible (N)
  • Modified Subsequent System Impact Integrity (MSI): Negligible (N)
  • Modified Subsequent System Impact Availability (MSA): Negligible (N)
  • Safety (S): Not Defined (X)
  • Automatable (AU): Not Defined (X)
  • Recovery (R): Not Defined (X)
  • Value Density (V): Not Defined (X)
  • Vulnerability Response Effort (RE): Not Defined (X)
  • Provider Urgency (U): Not Defined (X)
  • Confidentiality Req. (CR): Not Defined (X)
  • Integrity Req. (IR): Not Defined (X)
  • Availability Req. (AR): Not Defined (X)
  • Exploit Maturity (E): Not Defined (X)
created 2 weeks, 3 days ago Activity log
  • Created suggestion
Out-of-bounds write in Labcenter Proteus

The application contains an out-of-bounds write vulnerability that can be exploited by an attacker to cause the program to write data past the end of an allocated memory buffer. This can lead to arbitrary code execution.

Affected products

Proteus
  • ==9.1_SP4_Build-42914

Matching in nixpkgs

pkgs.proteus

Guitar amp and pedal capture plugin using neural networks

  • nixos-unstable 1.2
    • nixpkgs-unstable 1.2
    • nixos-unstable-small 1.2
  • nixos-26.05 1.2
    • nixos-26.05-small 1.2
    • nixpkgs-26.05-darwin 1.2
Dismissed
(not in Nixpkgs)
updated 3 months, 1 week ago by @LeSuisse Activity log
  • Created suggestion
  • @LeSuisse dismissed (not in Nixpkgs)
Labcenter Electronics Proteus PDSPRJ File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability

Labcenter Electronics Proteus PDSPRJ File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Labcenter Electronics Proteus. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of PDSPRJ files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-25719.

References

Affected products

Proteus
  • ==8.17 SP5

Matching in nixpkgs

pkgs.proteus

Guitar amp and pedal capture plugin using neural networks

  • nixos-unstable 1.2
    • nixpkgs-unstable 1.2
    • nixos-unstable-small 1.2
Dismissed
(not in Nixpkgs)
updated 3 months, 1 week ago by @LeSuisse Activity log
  • Created suggestion
  • @LeSuisse dismissed (not in Nixpkgs)
Labcenter Electronics Proteus PDSPRJ File Parsing Type Confusion Remote Code Execution Vulnerability

Labcenter Electronics Proteus PDSPRJ File Parsing Type Confusion Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Labcenter Electronics Proteus. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PDSPRJ files. The issue results from the lack of proper validation of user-supplied data, which can result in a type confusion condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-25717.

References

Affected products

Proteus
  • ==8.17 SP5

Matching in nixpkgs

pkgs.proteus

Guitar amp and pedal capture plugin using neural networks

  • nixos-unstable 1.2
    • nixpkgs-unstable 1.2
    • nixos-unstable-small 1.2
Dismissed
(not in Nixpkgs)
updated 3 months, 1 week ago by @LeSuisse Activity log
  • Created suggestion
  • @LeSuisse dismissed (not in Nixpkgs)
Labcenter Electronics Proteus PDSPRJ File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability

Labcenter Electronics Proteus PDSPRJ File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Labcenter Electronics Proteus. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PDSPRJ files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-25718.

References

Affected products

Proteus
  • ==8.17 SP5

Matching in nixpkgs

pkgs.proteus

Guitar amp and pedal capture plugin using neural networks

  • nixos-unstable 1.2
    • nixpkgs-unstable 1.2
    • nixos-unstable-small 1.2
Untriaged
created 3 months, 1 week ago Activity log
  • Created suggestion
Labcenter Electronics Proteus PDSPRJ File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability

Labcenter Electronics Proteus PDSPRJ File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Labcenter Electronics Proteus. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of PDSPRJ files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-25720.

References

Affected products

Proteus
  • ==8.17 SP5

Matching in nixpkgs

pkgs.proteus

Guitar amp and pedal capture plugin using neural networks

  • nixos-unstable 1.2
    • nixpkgs-unstable 1.2
    • nixos-unstable-small 1.2